{"product_id":"central-display-unit-and-horn-strobe-for-gas-safety-alarms","title":"Central Display Unit and Horn Strobe for Gas Safety Alarms","description":"\u003cp\u003eThe\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003eCentral Display Unit (\u003cspan\u003eRAD-CDU-HS1\u003c\/span\u003e) for Gas Safety Alarms with Horn Strobe\u003c\/strong\u003e is designed to provide real-time visibility of CO2 or O2 levels, alarms, and historical trends; enabling users to respond quickly to a potential gas hazard all from a single centralized display unit.\u003c\/p\u003e\n\u003cp\u003eThe CDU also serves as a critical source in ensuring compliance with industry regulations (OSHA\/NIOSH\/NBIC) by displaying the necessary data from the gas detection alarms across multiple locations from one dashboard.\u003c\/p\u003e\n\u003cp data-is-last-node=\"\" data-end=\"1556\" data-start=\"759\"\u003eWhen paired with the RAD-0102-6-HS2\u003cstrong data-end=\"858\" data-start=\"776\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eor\u003cstrong data-end=\"858\" data-start=\"776\"\u003e \u003c\/strong\u003eRAD-0002-ZR-HS2, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-end=\"895\" data-start=\"864\"\u003eCDU acts as the command hub\u003c\/strong\u003e, consolidating real-time gas readings and relaying critical alerts to safety personnel. \u003c\/p\u003e\n\u003cp\u003eTo get started, ensure you have a proper RAD-0102-6 or RAD-0002-ZR to integrate or \u003ca href=\"https:\/\/www.co2meter.com\/pages\/contact\" title=\"CO2 Sales Specialist\"\u003econtact a sales specialist\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003ewho can help you with a custom system for your application.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eConnects up to 12 gas sensors for visual display\u003c\/li\u003e\n\u003cli\u003e3 Relays\u003c\/li\u003e\n\u003cli\u003eAudible\/Visual Indicators\u003c\/li\u003e\n\u003cli\u003eIP54 Enclosure\u003c\/li\u003e\n\u003cli\u003eRelays control ventilation fans or signal a fire alarm panel\u003c\/li\u003e\n\u003cli\u003eLCD display clearly indicates current gas concentrations\u003c\/li\u003e\n\u003cli\u003eMeets NFPA, IFC, and NBIC Requirements | OSHA and NIOSH TWA standards\u003c\/li\u003e\n\u003cli\u003eMeets\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eall\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elocal inspection codes and requirements\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWorks With:\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.co2meter.com\/collections\/restaurants-food\/products\/co2-storage-safety-alarm\" title=\"Remote CO2 Storage Safety 3 Alarm\"\u003eRemote CO2 Storage Safety 3 Alarm (RAD-0102-6-HS2)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.co2meter.com\/collections\/restaurants-food\/products\/oxygen-deficiency-safety-alarm-monitor\" title=\"Oxygen Deficiency Depletion Safety Alarm\"\u003eOxygen Deficiency Depletion Safety Alarm (RAD-0002-ZR-HS2)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.co2meter.com\/collections\/restaurants-food\/products\/co2-storage-safety-alarm-sensor-horn-strobe\" title=\"Single Sensor CO2 Monitoring System and Horn Strobe\"\u003eSingle Sensor CO2 Monitoring System (RAD-SEU-HS1)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.co2meter.com\/collections\/fixed-wall-mount\/products\/oxygen-deficiency-depletion-safety-sensor-horn-strobe\" title=\"Single Sensor O2 Deficiency Monitoring System\"\u003eSingle Sensor O2 Deficiency Monitoring System (RAD-SEU-ZR-HS1)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.co2meter.com\/products\/power-monitor-gas-safety-alarms\" title=\"Power monitor Unit\"\u003ePower Monitor Unit (RAD-PMU)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCO2 Sensor Measurement 0-5% (0-50,000 ppm)\u003c\/li\u003e\n\u003cli\u003eO2 Sensor Range 0-25%\u003c\/li\u003e\n\u003cli\u003eAlarms (CO2) 5,000 ppm TWA, 5,000 ppm, 3% (user configurable)\u003c\/li\u003e\n\u003cli\u003eAlarms (O2) 19.5%, 16.5%, 12%\u003c\/li\u003e\n\u003cli\u003eMeasurement Interval 2 seconds (0.5 Hz)\u003c\/li\u003e\n\u003cli\u003eOperating Temperature 32-122° F (0-50° C)\u003c\/li\u003e\n\u003cli\u003eConnections Standard RJ45\u003cbr\u003eSensor Coverage Approximately 1,500 sq. ft.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eElectrical and Mechanical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePower Supply 100-240 VAC 50\/60 Hz to 12 VDC power adapter\u003c\/li\u003e\n\u003cli\u003eVoltage Range 9-32VDC\u003c\/li\u003e\n\u003cli\u003ePower Consumption 3 Watts\u003c\/li\u003e\n\u003cli\u003eAudible Alarm Level 88dB\u003c\/li\u003e\n\u003cli\u003eRelay Power Rating Peak current \u0026lt;2A @ 30 VDC or 250 VAC, SPDT\u003c\/li\u003e\n\u003cli\u003eRelay Connection Screw Terminal Connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 year - See \u003cstrong\u003e\u003ca href=\"https:\/\/www.co2meter.com\/pages\/terms-conditions\"\u003eCO2Meter Terms and Conditions.\u003c\/a\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDocuments\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003ca title=\"Data_Sheet_RAD-CDU-HS1_Central_Display_Unit_Horn_Strobe_CO2Meter\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/Data_Sheet_RAD-CDU-HS1_Central_Display_Unit_Horn_Strobe_CO2Meter.pdf?v=1752861479\"\u003e\u003cimg alt=\"RAD-CDU-HS1 Datasheet\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1092\"\u003e\u003cspan\u003e\u003cstrong\u003e Datasheet RAD-CDU-HS1 (pdf)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"CM 7000 - Multi Sensor System Datasheet Spanish\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/CO2METER_PDF.png?1092\"\u003e\u003cstrong\u003e\u003cspan\u003e \u003ca title=\"Central Display Unit Operation Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0019\/5952\/files\/RAD-CDU-Central-Display-Unit-CO2Meter-R.01.pdf?v=1742176105\"\u003eManual (pdf)\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"CO2Meter","offers":[{"title":"Default Title","offer_id":51231537791293,"sku":null,"price":375.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/0878\/9821\/files\/RAD_CDU-HS1.webp?v=1767907955","url":"https:\/\/hydroxchange.com\/products\/central-display-unit-and-horn-strobe-for-gas-safety-alarms","provider":"HydroXchange","version":"1.0","type":"link"}